Regulatory affairs (RA) is the discipline that gets safe, effective medical devices to patients—legally. It connects product teams, quality systems, and regulators so devices meet the rules before launch and keep meeting them afterward. Done well, RA protects patients, speeds market access, and prevents costly detours like recalls or warning letters.
The thread tying it all together is patient safety. Regulations require proof that benefits outweigh risks, plus continuous monitoring once devices are in use. That ongoing loop—evidence → authorization → surveillance—is what enables market access and protects public health
Key Responsibilities of Regulatory Affairs Professionals
We believe RA should front-load clarity—class, pathway, and evidence—so approvals move faster and post-market surprises shrink.
Product registration & approvals
Start with device classification and pick the right pathway per market. In the U.S., most devices follow 510(k) (substantial equivalence), De Novo (novel, low–moderate risk), or PMA (highest risk). Build a core dossier: device description, intended use, risk file, standards, bench/clinical data, labeling, and UDI plan. Map questions you’ll pre-answer in reviewer Q&A.
Regulatory strategy & submissions
Write the strategy like a test plan: which standards you claim, what evidence you’ll provide, and when each deliverable lands. In the U.S., follow FDA’s submission playbooks (e.g., 510(k)/De Novo content) and use recognized standards where possible; in the EU, align to MDR technical documentation (Annex II/III) and the chosen conformity route with your Notified Body. Keep a “living” gap list and pre-brief high-risk topics with the agency/NB.
Post-market surveillance (PMS) & reporting
After launch, RA runs vigilance: collect complaints and real-world signals, research papers, medical journals, trend issues, update labeling or controls, and file reports on time. U.S.: submit adverse events electronically via eMDR; FDA treats MDRs as a core surveillance tool. EU: maintain a PMS plan (Art. 83/84), produce PSUR/PMSR per class, and report serious incidents/field actions under Chapter VII; MDCG guidance gives PSUR structure and serious-incident criteria.
Global Regulatory Landscape
We believe “think global, build local” wins—standardize a core dossier, then localize to each regulator’s playbook.
U.S. — FDA
Risk-based classes (I–III) determine controls and the pathway: 510(k) (substantial equivalence), De Novo (novel, low–moderate risk), or PMA (Class III, clinical-evidence heavy). Keep your submission aligned to FDA’s templates and controls.
European Union — MDR/IVDR
CE marking under MDR 2017/745 (applicable May 26, 2021) and IVDR 2017/746 (applicable May 26, 2022) requires conformity assessment (often with a Notified Body), lifecycle PMS/PMCF, and UDI/EUDAMED actions, with evolving transition provisions.
Canada — Health Canada
Class I devices need an MDEL (establishment licence); Class II–IV require a Medical Device Licence (MDL) and must meet the Medical Devices Regulations (SOR/98-282) for labeling, safety/effectiveness, and recordkeeping.
Japan — PMDA/MHLW
Three routes: Todokede (Class I notification), Ninsho (third-party certification by Registered Certification Bodies for many Class II/III with standards), and Shonin (PMDA/MHLW approval for higher-risk or novel devices). All sit under the PMD Act with PMDA scientific review.
China — NMPA
Class I filing; Class II/III registration via CMDE technical review. The NMPA also operates special/urgent procedures (e.g., emergency registration) and continues policy updates affecting imported and domestically produced devices.
Medical Device Classification Systems
Smart classification is the speed cheat—get class right on Day 1 and your entire evidence, submission, and review timeline snaps into focus.
Here’s How devices are classified (U.S. & EU)
United States (FDA). Devices are risk-based: Class I, II, III. Class I is lowest risk; Class III is highest. Class drives the controls needed to assure safety and effectiveness (general, special, or PMA-level controls). Many Class I are 510(k)-exempt; most Class II need a 510(k); most Class III require PMA.
European Union (MDR 2017/745). Devices are Class I, IIa, IIb, III per Article 51 and the detailed Annex VIII rules (intended purpose, invasiveness, duration, active features, software Rule 11, etc.). Classification determines the conformity assessment route and Notified Body involvement.
Impact of classification on the regulatory pathway
- U.S.:
-
- Class I → often 510(k)-exempt (still subject to general controls).
-
- Class II → typically 510(k) with special controls as applicable.
-
- Class III → PMA with valid scientific evidence (clinical data common).
- EU:
-
- Class I (some subtypes self-declare) vs. Class IIa/IIb/III (Notified Body review).
-
- Route selected from Annex IX (QMS + technical documentation), Annex X (type-examination), or Annex XI (product conformity verification) based on class and risk.
Quick rule of thumb: higher class = deeper evidence, more third-party review, and tighter post-market obligations. (Yes, your budget will feel it.)
Regulatory Submissions & Approval Pathways
In the United States, your pathway defines both the evidence bar and how reviewers will read your file. Most moderate-risk devices clear via 510(k) by demonstrating substantial equivalence to a legally marketed predicate; novel, low-to-moderate-risk products use De Novo to establish a new Class I/II regulation; highest-risk devices require PMA, a full scientific review often supported by clinical studies. Building to FDA’s own structure—device description, risk management, standards and test data, labeling/UDI, then clinical where needed—reduces “please provide…” cycles. Note the digital shift as well: FDA’s eSTAR template is now the preferred format for device submissions and becomes required for De Novo on October 1, 2025.
In the European Union, CE marking under MDR 2017/745 is achieved through conformity assessment against the General Safety and Performance Requirements and a technical file structured to Annex II/III. For most non-Class I devices, a Notified Body reviews the QMS and technical documentation, including clinical evaluation and lifecycle plans for PMS/PMCF and UDI registration. Teams that mirror the Annex II/III table of contents—claim-to-evidence mapping, risk files per ISO 14971, and clear links to clinical/performance data—see smoother reviews and fewer round-trips.
Beyond the U.S. and EU, country rules add local nuances that are easy to miss if you don’t plan them early. Canada requires an establishment licence (MDEL) for sellers/importers and a product-level MDL for Class II–IV devices; licence status is publicly traceable. Japan routes depend on risk: Todokede notification (Class I), Ninsho certification via Registered Certification Bodies (many Class II/III), and Shonin approval with PMDA review for higher-risk or novel devices. China follows NMPA filing for Class I and registration (with CMDE technical review) for Class II/III, with frequent policy updates that can affect test plans and timelines. Aligning a “core dossier” to these specifics—then localizing annexes—prevents late refactoring.
Clinical Evidence & Performance Evaluation
Clinical evidence is the backbone of device claims, and the bar is set by region. In the EU, MDR 2017/745 Article 61 and Annex XIV require a documented clinical evaluation scaled to risk—drawing on literature, equivalence (when justified), investigations, and ongoing updates. For higher-risk and implantable devices, clinical investigations are generally expected unless specific exemptions apply. The point isn’t volume; it’s relevance and traceability from intended use to outcomes, with a plan to keep that evidence current across the lifecycle.
Clinical data no longer means “trial or bust.” The FDA accepts real-world evidence (RWE)—from registries, EHRs, and claims—when data quality and methods are fit for purpose. The 2017 final guidance (still in effect) lays out how RWD can support decisions; a Dec 18, 2023 draft proposes updates that expand recommendations while the 2017 guidance remains controlling until finalized. Practically, that means pre-specifying endpoints, addressing bias, and showing data provenance so reviewers can trust the signal, not just the sample size.
After launch, the EU expects Post-Market Clinical Follow-up (PMCF) to keep the clinical picture “live.” MDCG 2020-7 provides a PMCF Plan template; MDCG 2020-8 provides the Evaluation Report template. Findings must feed back into the clinical evaluation, risk file, PMS plan, and—where needed—labeling or design controls. Treat PMCF as a standing program with defined methods (surveys, registries, targeted studies), triggers, and timelines—not a one-off exercise
Quality Management Systems (QMS) & Standards
Quality isn’t a binder—it’s a system that ties design, manufacturing, and vigilance into one traceable thread. Globally, the backbone is ISO 13485 for medical-device QMS. In the United States, FDA has finalized the Quality Management System Regulation (QMSR) to align Part 820 with ISO 13485; the final rule was published February 2, 2024 and becomes effective February 2, 2026. In practice, this means U.S. manufacturers will operate to an ISO-13485–aligned rulebook while still meeting device-specific FDA requirements (e.g., labeling, reporting). Federal Register
Europe takes a similar route through EN ISO 13485:2016 (with A11:2021 amendment and AC:2018 corrigendum) listed as a harmonized standard under the MDR, giving presumption of conformity to relevant quality clauses when properly applied. For manufacturers, this reduces duplicate effort: the same QMS spine can support both CE marking and U.S. expectations, provided the technical documentation and vigilance processes meet each region’s specifics. EUR-Lex+1
Risk ties it together. ISO 14971:2019 defines the lifecycle risk-management process—from identifying hazards to verifying controls and monitoring post-market effectiveness—and is FDA-recognized, with companion guidance (e.g., AAMI/ISO TR 24971) and security-risk extensions (e.g., standards that embed cybersecurity into the ISO 14971 framework). Treat the risk file as a living artifact that links design controls, clinical evaluation, labeling, and PMS/PMCF so changes stay safe and auditable.
Labeling, UDI, and Documentation Requirements
Labeling is part of design, not an afterthought. In the U.S., FDA rules live in 21 CFR Part 801 and spell out what must appear on the label and what counts as “labeling” (IFUs, brochures, digital content). Subpart B ties labeling to the UDI framework, while 21 CFR Part 830 defines the UDI system itself and the obligation to submit device identifier records to FDA’s GUDID (Global Unique Device Identification Database) so products are traceable in the field. In practice: lock claims and required statements early, plan your UDI-DI/UDI-PI assignment, and make sure what’s on the carton matches what’s in GUDID.
Europe takes a lifecycle view. MDR Annex I, Chapter III (§23) details the information supplied by the manufacturer (labels, IFU, symbols, languages). The UDI scheme is set by Article 27 and Annex VI Part C and connects to the EUDAMED UDI/device-registration module now available. For certain devices, the EU permits electronic IFU (eIFU) under Commission Implementing Regulation (EU) 2021/2226, provided risk controls and paper-on-request are in place. Translation: treat language management, symbols, and eIFU eligibility as design inputs, not late-stage chores. Documentation pulls it all together. In the EU, your technical documentation must mirror MDR Annex II/III (claims→evidence mapping, risk management, clinical evaluation, PMS plan, and PMCF where applicable). In the U.S., the core records remain the Design History File (DHF), Device Master Record (DMR), and Device History Record (DHR) under 21 CFR 820—concepts that continue to matter as FDA’s QMSR aligns with ISO 13485 by February 2, 2026. The practical habit is to keep a “living” file: when labeling or UDI change, update the tech file/DHF and push the change through DMR and DHR so auditors (and your future self) can trace every decision.
Post-Market Surveillance & Vigilance Reporting
Post-market is where your file proves it can breathe. In the U.S., adverse events flow to FDA electronically via eMDR, which standardizes submissions and speeds signal detection across manufacturers and importers; the legal backbone is 21 CFR Part 803. Build complaint intake and medical review so triage, causality, and reportability decisions map cleanly to MDR rules—and test that your data can move without manual rework.
Europe takes a lifecycle view: your PMS plan must be proportionate to risk and integrated with the QMS (MDR Article 83), with outputs like PSUR/PMSR feeding labeling, risk controls, and, when needed, field safety notices. Treat PSUR as a standing product “health report,” not a once-a-year scramble; the Commission’s MDCG guidance spells out structure and expectations.
When issues trend, CAPA closes the loop. Procedures should capture root cause, corrective action, and effectiveness checks—then verify that fixes hold in the field. U.S. expectations are explicit in 21 CFR 820.100, and even as FDA transitions to the QMSR in 2026, CAPA discipline remains central to both ISO 13485 and U.S. practice. Align CAPA inputs with complaint and vigilance data so fixes land where risk actually lives.
Finally, tighten safety communication mechanics before you need them. In the EU, the updated Manufacturer Incident Report (MIR) v7.3.1 becomes mandatory from November 2025, standardizing serious-incident reporting to authorities and EUDAMED; make sure your templates and workflows are ready.
Challenges in Medical Device Regulatory Affairs
Keeping up with evolving global regulations: Timelines, templates (e.g., eSTAR in the U.S.), and guidance (e.g., cybersecurity) change fast. RA teams need active horizon scanning and early Notified Body engagement.
Market delays and resource challenges: Limited Notified Body capacity in the EU, clinical evidence upgrades for legacy products, and multi-region variations can stretch budgets and schedules. Plan buffers and parallelize workstreams where you can.
Future Trends in Regulatory Affairs
AI and digital health regulations: FDA finalized guidance on Predetermined Change Control Plans (PCCP) for AI-enabled devices and continues to expand digital health expectations; IMDRF SaMD documents remain the global foundation.
Harmonization efforts (IMDRF, MDSAP): IMDRF aligns concepts (e.g., SaMD, codes, ToC) across authorities; MDSAP offers one audit for multiple markets—more efficiency, less audit fatigue.
Increasing focus on cybersecurity and software as a medical device (SaMD): FDA refreshed its premarket cybersecurity guidance in 2025; ISO/IEC security risk standards are FDA-recognized. Expect deeper SBOMs, patching plans, and secure-by-design expectations.
Conclusion
We believe the best regulatory strategy is operational, not ornamental—built into daily work so evidence is always audit-ready. Across the journey you’ve seen the pattern: classification sets the bar, pathway defines the file, QMS and risk keep it coherent, labeling/UDI make it traceable, and PMS/PMCF keep it honest after launch. What separates smooth approvals from stalled ones isn’t more pages—it’s tighter linkage between claims, tests, clinical rationale, and post-market signals. Treat your technical documentation as living: update when design or labeling shifts, surface risks early, and plan change control for software and AI up front. Do that, and market access becomes repeatable rather than heroic.